MFR #:Sterling® U-475
EIS #:PH21-Sterling U-475
MFR #:Sterling® U-475
EIS #:PH21-Sterling U-475
Elantas PDG Sterling® U-475 Solvent-Borne Impregnating Resin, Epoxy Base Type, Oven Cure Type, >3600 V/Mil (Dry), >2800 V/Mil (Wet) Dielectric Strength, 29 °C Flash Point, 2 hr At 175 °C or 4 hr At 150 °C Full Cure Time, 180 °C Temperature Rating, 180 - 250 CP At 25 °C Viscosity. - Sterling® U-475 EH is a solvent-borne epoxy impregnating resin featuring outstanding resistance to chemicals, including refrigerants.
$18.94
- $19.73
Select from the options below
Elantas PDG Sterling® U-475 Solvent-Borne Impregnating Resin, Epoxy Base Type, Oven Cure Type, >3600 V/Mil (Dry), >2800 V/Mil (Wet) Dielectric Strength, 29 °C Flash Point, 2 hr At 175 °C or 4 hr At 150 °C Full Cure Time, 180 °C Temperature Rating, 180 - 250 CP At 25 °C Viscosity. - Sterling® U-475 EH is a solvent-borne epoxy impregnating resin featuring outstanding resistance to chemicals, including refrigerants.
Product Options
Showing 2 out of 2 options
Container Size: 486 lb | EIS Part #: U475EH486LB | $ / US pound | ||
Container Size: 44 lb | EIS Part #: U475EH44LB | $ / US pound |
- Attributes
- Features
- Applications
- Documents
Attributes
General Information
Item NameImpregnating Resin
Trade NameSterling®
SeriesSterling® U-475
General Features
Shelf Life12 Months
TypeSolvent-Borne
Design & Construction
Base TypeEpoxy
ColorNatural
Cure TypeOven Cure
FormLiquid
Performance Details
Full Cure Time2 hr at 175 °C or 4 hr at 150 °C
Technical Details
Flash Point29 °C
Chemical Properties
Viscosity180 cP
Electrical Properties
Dielectric Strength3600 V/Mil
Physical Properties
Container TypeDrum
Environmental Condition
Temperature Rating180 °C
Features
- Low viscosity for excellent penetration
- Moisture and chemical resistant
- Excellent tank stability
- High bond strength
- Secondary insulation
- Dielectric Strength: >3600 V/Mil (Dry), >2800 V/Mil (Wet)
- Viscosity: 180 - 250 CP at 25 °C
- Viscosity: 180 - 250 cP
Applications
- For Impregnation of Motor Windings Used in Hermetic Compressors and Other Refrigeration Systems, Impregnation and Overcoating of Motors, Transformers and Other Electrical Devices in Severe Duty Applications